Description |
Model Numbers |
 |
Incandescent Dimmers with IR Receiver |
 |
600 Watt single-location |
SPS-600- |
| 600 Watt multi-location |
SPS-600M- |
| 1000 Watt single-location |
SPS-1000- |
| 1000 Watt multi-location |
SPS-1000M- |
Dimmers have the built-in ability to store 4 lighting scenes. For multi-location dimming, use a multi-location dimmer with Spacer System companion dimmers, SPS-AD-. Not for use with mechanical 3-way or 4-way switches. Minimum load is 60W.
|
 |
Electronic Low-Voltage Dimmers with IR Receiver |
 |
600 Watt Single Location |
SPSELV-600- |
| 600 Watt Multi-Location |
SPSELV-600M- |
Dimmers have the built-in ability to store 4 lighting scenes. For multi-location dimming, use a multi-location dimmer with Spacer System companion dimmers, SPS-AD-. Not for use with mechanical 3-way or 4-way switches. Requires neutral wire connection. Minimum load is 5W.
|
 |
Magnetic Low-Voltage Dimmers with IR Receiver |
 |
600 VA (450 Watt) single-location |
SPSLV-600- |
| 600 VA (450 Watt) multi-location |
SPSLV-600M- |
| 1000 VA (800 Watt) single-location |
SPSLV-1000- |
| 1000 VA (800 Watt) multi-location |
SPSLV-1000M- |
Dimmers have the built-in ability to store 4 lighting scenes. For multi-location dimming, use a multi-location dimmer with Spacer System companion dimmers, SPS-AD. Not for use with mechanical 3-way or 4-way switches. Minimum load is 60W.
|
 |
Fluorescent Dimmers with IR Receiver (2-wire)
for Lutron Tu-Wire® Ballasts |
 |
| 120 Volt, 5A single-location |
SPSFTU-5A- |
Dimmers have the built-in ability to store 4 lighting scenes. Use with Lutron Tu-Wire line voltage controlled electronic dimming ballasts only. Minimum load is 2 ballasts/250mA.
|
 |
Fluorescent Dimmers with IR Receiver (3-wire)
for Lutron Hi-lume®, Hi-lume 3D, and Eco-10® Ballasts
|
 |
| 120 Volt, 20 ballasts, 6A single-location |
SPSF-6A- |
| 120 Volt, 20 ballasts, 6A multi-location |
SPSF-6AM- |
| 277 Volt, 20 ballasts, 6A single-location |
SPSF-6A-277- |
| 277 Volt, 20 ballasts, 6A multi-location |
SPSF-6AM-277- |
| Dimmers have the built-in ability to store 4 lighting scenes. For multi-location dimming, use one Spacer System multi-location dimmer with up to nine Spacer System companion dimmers, SPS-AD- or SPS-AD-277-. Not for use with mechanical 3-way or 4-way switches. Use with Lutron Hi-lume, Hi-lume 3D, and Eco-10 (ECO Series) line voltage 3-wire control electronic dimming ballasts only. Requires neutral wire connection. No derating required if ganged. Minimum load is 1 ballast/90mA. |