Lutron - High Performance LED Fixture List
Loading...

Filters

[Start Over]

Results 1-25 of 325

Lutron Driver Family, Control Protocol and Dimming Level
Hi-lume
Premier 0.1%
Hi-lume Premier
0.1% with Soft-on,
Fade-to-Black
Hi-lume 1% (formerly A-Series) Hi-lume 1% with
Soft-on, Fade-to-Black
(formerly H-Series)
5-Series 5% Lutron Embedded EcoSystem Chip
Fixture Classification Manufacturer Manufacturer Fixture Family Dimensions Lumen Output Color Temp (K) 3-wire (L3D03W) EcoSystem (L3D0E) 2-wire 120V (LTEA2W) 3-wire (L3DA3W) EcoSystem (L3DAE) EcoSystem (LDE1) EcoSystem (LDE5)
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 2" 1004 2700, 3000, 3500, 4000 No No Yes* Yes* Yes* No No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 2" 1570 2700, 3000, 3500, 4000 No No Yes* Yes* Yes* No No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 2" 1588 2700, 3000, 3500, 4000 No No Yes* Yes* Yes* No No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 2" Custom-Consult Mfr. 2700, 3000, 3500, 4000 No No No Yes* Yes* No No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 2" Custom-Consult Mfr. 2700, 3000, 3500, 4000 No No No Yes* Yes* No No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 5 80,90CRI 3.5'' 800 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 5 80,90CRI 3.5'' 1000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 5 80,90CRI 3.5'' 1400 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 5 80,90CRI 3.5'' 1700 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Adjustable ConTech (Leviton) R2ANC 93CRI 2" Custom-Consult Mfr. 2700, 3000, 3500, 4000 No No Yes* Yes* Yes* No No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4IC 80,90CRI 4.75'' 1000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4IC 80,90CRI 4.75'' 1400 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4IC 80,90CRI 4.75'' 2000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4IC 80,90CRI 4.75'' 2600 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4NC 80,90CRI 4.75'' 1000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4NC 80,90CRI 4.75'' 1400 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4NC 80,90CRI 4.75'' 2000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4NC 80,90CRI 4.75'' 2600 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4NC 80,90CRI 4.75'' 3200 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4NC 80,90CRI 4.75'' 3600 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4SA 80,90CRI 4'' 1000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4SA 80,90CRI 4'' 1400 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4SA 80,90CRI 4'' 2000 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4SA 80,90CRI 4'' 2600 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
Recessed, Downlight-round, Direct ConTech (Leviton) R4SA 80,90CRI 4'' 3200 2700, 3000, 3500, 4000 No No Yes* No No Yes* No No
*This fixture is available with the Driver Type, Control Protocol & Dimming Range indicated. Please contact the fixture manufacturer for verification of the number of drivers utilized in each fixture.
Note: Fixture information provided in this tool has been obtained from the fixture manufacturer's specification submittal. Please review the fixture specification submittal prior to specifying fixture to ensure that the fixture meets all your project's specification needs.
X